No.BA108
The BA108 is an industrial air conditioning protocol converter with Ethernet ports and RS-232/485 serial ports. BLIIOT BA108 industrial air conditioning protocol converter supports air conditioning protocols to BACnet/IP protocol. 
Communication
Ethernet, WiFi
Downlink Protocol
Various air conditioning protocols, Modbus RTU, Modbus TCP
Uplink Protocol
BACnet MS/TP, BACnet/IP
Serial Port
2CH or 6CH RS485/RS232
Baud Rate
2400bps-115200bps
Ethernet Port
1 WAN + 1 LAN
Description

HVAC / Modbus to BACnet Gateway

BA108 Series · Bridge air conditioning systems, VRF, chillers & Modbus devices to BACnet BMS

2 or 6 serial ports 4,000 data points HVAC protocols · Modbus RTU/TCP BACnet/IP · BACnet MS/TP Optional WiFi
❄️
BA108 2‑Port BA108P 6‑Port
Supports 10–50 devices · 512–4,000 data points · Optional WiFi
⬇ HVAC · VRF · Chillers · Modbus ⬆ BACnet/IP & MS/TP
📡 WiFi 🔌 Ethernet

📊 BA108 vs BA108P – Side‑by‑Side

Choose BA108 for cost‑efficient small building zones, or BA108P for high‑density data acquisition across large facilities. Both support optional WiFi.

Feature BA108 (Standard) BA108P (High‑Performance)
Serial Channels 2 × RS485/RS232 6 × RS485/RS232
Max. Devices 10 50
Data Points 512 4,000
Downlink Protocols HVAC · VRF · Chillers · Modbus RTU/TCP HVAC · VRF · Chillers · Modbus RTU/TCP
Uplink Protocols BACnet/IP · BACnet MS/TP BACnet/IP · BACnet MS/TP
WiFi (Optional) 802.11a/b/g/n 802.11a/b/g/n
Dimensions (L×W×H) 30 × 83 × 110 mm 40 × 83 × 110 mm
Weight 133 g 171 g
Best Fit Small Buildings / Zones Large Facilities / Campuses
💡 Quick rule: ≤ 10 devices → BA108  |  > 10 devices → BA108P  |  📡 WiFi available for both models
⚡ CUSTOMER VALUE

Bridge HVAC Systems & Modbus to BACnet BMS

  • Native HVAC Protocol Conversion
    Directly connect VRF systems, chillers, AHUs, and air conditioning controllers to BACnet BMS — no middleware or third-party gateways required.
  • HVAC to Building Automation
    Bridge HVAC equipment and Modbus devices into BACnet-based building management systems — unify climate control and facility data.
  • Zero On‑Site Maintenance
    Remote configuration, firmware upgrades, and system monitoring — significantly reduces travel costs and response time.
🏭 -40°C ~ 85°C 🛡️ EMC Level 3 🔒 2KV Isolation

📡 TYPICAL DATA FLOW ARCHITECTURE

VRF · Chillers · AHUs · Modbus
HVAC Protocols · Modbus RTU/TCP
BA108 / P
HVAC/Modbus → BACnet
🔌 ETH📡 WiFi
BACnet/IP BACnet MS/TP BMS
Building Management System

🚀 Core Advantages

Engineered for HVAC-to-building automation integration with seamless IT/OT convergence.

🔄

Native HVAC Protocol Conversion

Direct downlink support for air conditioning systems, VRF, chillers, and AHUs — plus Modbus RTU/TCP. Uplink to BACnet/IP and BACnet MS/TP.

❄️

HVAC-to-Building Bridge

Unify HVAC system data with building management systems — enable centralized climate control and energy optimization.

🏢

BMS‑Ready Integration

Works seamlessly with all major BMS platforms — Siemens Desigo, Honeywell Niagara, Johnson Controls Metasys, Schneider Electric EcoStruxure, and more.

📶

Flexible Connectivity

Ethernet or optional WiFi — deploy in existing building networks without additional cabling. Remote access via OpenVPN.

🏭

Industrial‑Grade Durability

9–36V DC wide input, reverse‑polarity protection, -40~85°C operation, EMC Level 3 (ESD/EFT/Surge), 2KV isolation.

🔧

Flexible Mounting

DIN35 rail or wall mounting with patented rail‑clip — quick installation in electrical panels, chiller plants, and equipment rooms.

📋 Technical Specifications

Click a tab below for detailed module parameters. Both models share the same core platform.

System & Power Serial & Ethernet WiFi (Optional) Environment & Cert.
ProcessorARM MCU, 300MHz
Storage128MB Storage · 64MB Flash
Input VoltageDC 9~36V (wide range)
Power Consumption70mA@12V (typ) · 168mA@12V (max)
ProtectionReverse‑polarity protection
WatchdogHW + SW dual watchdog (auto‑reboot < 3s)
USB2× Micro (OTG), over‑current protection
ProtocolsHVAC · VRF · Chillers · Modbus RTU/TCP · BACnet/IP · BACnet MS/TP
* Full details in the product datasheet

🏢 Typical Applications

Trusted by HVAC system integrators, building automation engineers, and facility managers.

❄️

HVAC Building Automation

Connect VRF systems, chillers, AHUs, and air conditioning controllers to BACnet BMS for centralized climate control.

🏢

Smart Building Management

Unify HVAC system data with building automation platforms for intelligent, energy-efficient facility operations.

Energy Monitoring & Optimization

Collect energy data from HVAC systems and Modbus power meters for BACnet-based energy management and optimization.

🏭

Industrial Facility Management

Bridge HVAC equipment and Modbus devices in industrial facilities to BACnet BMS for complete facility oversight.

  • Air Conditioning to BACnet Gateway
  • Air Conditioning to BACnet Gateway
  • Air Conditioning to BACnet Gateway
  • Air Conditioning to BACnet Gateway
  • Air Conditioning to BACnet Gateway

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
Leave a message
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.