Modbus BACnet to Modbus BAS Industrial Protocol Gateway BA111
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway

Modbus BACnet to Modbus BAS Industrial Protocol Gateway BA111

No.BA111
BLIIoT BA111 protocol converter translates BACnet/IP, BACnet MS/TP, Modbus RTU, Modbus TCP to Modbus RTU, Modbus TCP protocols.
Communication
Ethernet, 4G, WiFi
Downlink Protocol
Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet/IP
Uplink Protocol
Modbus RTU, Modbus TCP
Serial Port
2CH or 6CH RS485/RS232
Baud Rate
2400bps-115200bps
Ethernet Port
1 WAN + 1 LAN
Description

BACnet to Modbus Gateway

BA111 Series · Connect BACnet HVAC Devices to Modbus Control Systems

2 or 6 serial ports 4,000 data points BACnet/IP · BACnet MS/TP Modbus RTU · Modbus TCP 4G / WiFi / GPS optional
🏢
BA111 2‑Port BA111P 6‑Port
Supports 10–50 devices · 512–4,000 data points · Optional 4G/WiFi/GPS
⬇ BACnet/IP & MS/TP ⬆ Modbus RTU & TCP
📶 4G 📡 WiFi 📍 GPS

📊 BA111 vs BA111P – Side‑by‑Side

Choose BA111 for cost‑efficient small building zones, or BA111P for high‑density data acquisition across large facilities. Both support optional 4G, WiFi, and GPS modules.

Feature BA111 (Standard) BA111P (High‑Performance)
Serial Channels 2 × RS485/RS232 6 × RS485/RS232
Max. Devices 10 50
Data Points 512 4,000
Downlink Protocols BACnet/IP · BACnet MS/TP BACnet/IP · BACnet MS/TP
Uplink Protocols Modbus RTU · Modbus TCP Modbus RTU · Modbus TCP
4G (Optional) L‑E / L‑A / L‑AU / L‑AF / CAT‑1 L‑E / L‑A / L‑AU / L‑AF / CAT‑1
WiFi (Optional) 802.11a/b/g/n 802.11a/b/g/n
GPS (Optional) NMEA‑0183 NMEA‑0183
Dimensions (L×W×H) 30 × 83 × 110 mm 40 × 83 × 110 mm
Weight 133 g 171 g
Best Fit Small Buildings / Zones Large Facilities / Campuses
💡 Quick rule: ≤ 10 devices → BA111  |  > 10 devices → BA111P  |  📶 4G/WiFi/GPS available for both models
⚡ CUSTOMER VALUE

Connect BACnet HVAC Devices to Modbus Control Systems

  • BACnet to Modbus – Reverse Protocol Conversion
    Native conversion from BACnet/IP and BACnet MS/TP to Modbus RTU and Modbus TCP — enabling BACnet HVAC devices to communicate with Modbus-based control systems.
  • Connect BACnet HVAC to Modbus Controls
    Bridge BACnet chillers, AHUs, and thermostats to Modbus PLCs and SCADA systems — unify building HVAC with industrial control infrastructure.
  • Data Catch‑up on Network Recovery
    Automatically caches data locally during network outages and retransmits upon reconnection — ensures zero data loss and complete historical traceability.
🏭 -40°C ~ 85°C 🛡️ EMC Level 3 🔒 2KV Isolation

📡 TYPICAL DATA FLOW ARCHITECTURE

BACnet HVAC Devices
BACnet/IP · BACnet MS/TP
BA111 / P
BACnet → Modbus
📶 4G🔌 ETH📡 WiFi
Modbus RTU Modbus TCP PLCs · SCADA · Controls
Modbus Control Systems

🚀 Core Advantages

Engineered for building-to-industrial automation integration with seamless BACnet-to-Modbus connectivity.

🔄

BACnet to Modbus Conversion

Native downlink BACnet/IP and BACnet MS/TP — uplink Modbus RTU and Modbus TCP. Enable BACnet HVAC devices to communicate with Modbus control systems.

🏭

Building-to-Industrial Bridge

Connect BACnet HVAC equipment — chillers, AHUs, thermostats — to Modbus PLCs and SCADA for unified building and industrial control.

📶

Universal Connectivity

4G, WiFi, or Ethernet with wired priority and automatic 4G failover — always online. Optional GPS for asset tracking.

🏭

Industrial‑Grade Durability

9–36V DC wide input, reverse‑polarity protection, -40~85°C operation, EMC Level 3 (ESD/EFT/Surge), 2KV isolation.

🌐

Remote Lifecycle Management

Full remote configuration, firmware upgrades, and diagnostics — eliminate costly on‑site visits.

🔧

Flexible Mounting

DIN35 rail or wall mounting with patented rail‑clip — quick installation in electrical panels and equipment rooms.

📋 Technical Specifications

Click a tab below for detailed module parameters. Both models share the same core platform.

System & Power Serial & Ethernet 4G / WiFi / GPS Environment & Cert.
ProcessorARM MCU, 300MHz
Storage128MB Storage · 64MB Flash
Input VoltageDC 9~36V (wide range)
Power Consumption70mA@12V (typ) · 168mA@12V (max)
ProtectionReverse‑polarity protection
WatchdogHW + SW dual watchdog (auto‑reboot < 3s)
SIM Card1 × NANO, drawer type, 1.8V/3V
USB2× Micro (OTG), over‑current protection
* Full details in the product datasheet

🏢 Typical Applications

Trusted by building system integrators, facility managers, and industrial automation engineers.

🏭

Integrating BACnet HVAC Devices into Industrial Control Systems

Connect BACnet-based chillers, AHUs, and thermostats to industrial Modbus PLCs and SCADA — unify HVAC with production control.

Connecting BACnet Building Equipment to Energy Management Platforms

Bridge BACnet building equipment to Modbus-based energy management systems for centralized energy monitoring and optimization.

🏢

BACnet Device Integration in Industrial Facilities

Integrate BACnet lighting, access control, and environmental sensors into industrial Modbus networks for unified facility oversight.

🔄

Legacy Modbus Platform Expansion with BACnet Devices

Extend existing Modbus-based control platforms to include BACnet devices — modernize without replacing legacy infrastructure.

  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway
  • BACnet to Modbus Gateway

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
Leave a message
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.