Modbus BACnet to MQTT IBMS Industrial IoT Gateway BA113
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway

Modbus BACnet to MQTT IBMS Industrial IoT Gateway BA113

No.BA113
Modbus, BACnet to MQTT IBMS Industrial IoT gateways ensure that OT device data is propagated in the cloud for production monitoring. BLIIoT BA113 IBMS IoT gateway supports Modbus RTU, Modbus TCP, BACnet/IP, BACnet MS/TP, converting to MQTT protocols.  
Description

BACnet / Modbus to MQTT Cloud Gateway

BA113 Series · Bridge BACnet and Modbus building devices to AWS IoT, ThingsBoard, Ignition, HUAWEI IoT, and ALI IoT

2 or 6 serial ports 4,000 data points BACnet · Modbus → MQTT 4G / WiFi / GPS optional -40~85°C wide temp
☁️
BA113 2‑Port BA113P 6‑Port
Supports 10–50 devices · 512–4,000 data points · Optional 4G/WiFi/GPS
⬇ BACnet/IP & MS/TP ⬇ Modbus RTU & TCP ⬆ MQTT
☁️ AWS IoT 📊 ThingsBoard ⚡ Ignition SCADA 🔷 HUAWEI IoT 🔶 ALI IoT
📶 4G 📡 WiFi 📍 GPS

📊 BA113 vs BA113P – Side‑by‑Side

Choose BA113 for cost‑efficient small building zones, or BA113P for high‑density data acquisition across large facilities. Both support optional 4G, WiFi, and GPS modules.

Feature BA113 (Standard) BA113P (High‑Performance)
Serial Channels 2 × RS485/RS232 6 × RS485/RS232
Max. Devices 10 50
Data Points 512 4,000
Downlink Protocols BACnet/IP · BACnet MS/TP · Modbus RTU/TCP BACnet/IP · BACnet MS/TP · Modbus RTU/TCP
Uplink Protocols MQTT MQTT
Cloud Drivers AWS IoT · ThingsBoard · Ignition · HUAWEI IoT · ALI IoT AWS IoT · ThingsBoard · Ignition · HUAWEI IoT · ALI IoT
4G (Optional) L‑E / L‑A / L‑AU / L‑AF / CAT‑1 L‑E / L‑A / L‑AU / L‑AF / CAT‑1
WiFi (Optional) 802.11a/b/g/n 802.11a/b/g/n
GPS (Optional) NMEA‑0183 NMEA‑0183
Dimensions (L×W×H) 30 × 83 × 110 mm 40 × 83 × 110 mm
Weight 133 g 171 g
Best Fit Small Buildings / Zones Large Facilities / Campuses
💡 Quick rule: ≤ 10 devices → BA113  |  > 10 devices → BA113P  |  📶 4G/WiFi/GPS available for both models
⚡ CUSTOMER VALUE

Bridge BACnet & Modbus to Cloud

  • Native Cloud Integration
    Native drivers for AWS IoT Core, ThingsBoard, Ignition SCADA, HUAWEI IoT, and ALI IoT — no scripting, just configuration.
  • Building Data to the Cloud
    Securely publish BACnet and Modbus building data to cloud platforms via MQTT for remote monitoring, analytics, and control.
  • Data Catch‑up on Network Recovery
    Automatically caches data locally during network outages and retransmits upon reconnection — ensures zero data loss and complete historical traceability.
🏭 -40°C ~ 85°C 🛡️ EMC Level 3 🔒 2KV Isolation

📡 TYPICAL DATA FLOW ARCHITECTURE

BACnet / Modbus Devices
BACnet/IP · MS/TP · Modbus RTU/TCP
BA113 / P
BACnet/Modbus → MQTT
📶 4G🔌 ETH📡 WiFi
AWS IoT ThingsBoard Ignition HUAWEI ALI IoT
MQTT

🚀 Core Advantages

Engineered for building-to-cloud integration with seamless BACnet/Modbus to MQTT connectivity.

🔄

BACnet/Modbus to MQTT

Native downlink BACnet/IP, BACnet MS/TP, Modbus RTU, and Modbus TCP — uplink MQTT. Connect building devices to any cloud platform.

☁️

Global Cloud Ecosystem

Native drivers for AWS IoT Core, ThingsBoard, Ignition SCADA, HUAWEI IoT, ALI IoT — also supports any MQTT broker.

📶

Universal Connectivity

4G, WiFi, or Ethernet with wired priority and automatic 4G failover — always online. Optional GPS for asset tracking.

🏭

Industrial‑Grade Durability

9–36V DC wide input, reverse‑polarity protection, -40~85°C operation, EMC Level 3 (ESD/EFT/Surge), 2KV isolation.

🌐

Remote Lifecycle Management

Full remote configuration, firmware upgrades, and diagnostics — eliminate costly on‑site visits for building maintenance.

🔧

Flexible Mounting

DIN35 rail or wall mounting with patented rail‑clip — quick installation in electrical panels and equipment rooms.

📋 Technical Specifications

Click a tab below for detailed module parameters. Both models share the same core platform.

System & Power Serial & Ethernet 4G / WiFi / GPS Environment & Cert.
ProcessorARM MCU, 300MHz
Storage128MB Storage · 64MB Flash
Input VoltageDC 9~36V (wide range)
Power Consumption70mA@12V (typ) · 168mA@12V (max)
ProtectionReverse‑polarity protection
WatchdogHW + SW dual watchdog (auto‑reboot < 3s)
SIM Card1 × NANO, drawer type, 1.8V/3V
USB2× Micro (OTG), over‑current protection
* Full details in the product datasheet

🏢 Typical Applications

Trusted by building system integrators, facility managers, and cloud IoT engineers.

☁️

Smart Building Cloud Monitoring

Publish BACnet and Modbus building data to AWS IoT, ThingsBoard, or Ignition for centralized cloud-based monitoring and alerting.

🌐

Multi-Site Building Management

Aggregate data from multiple buildings across regions via MQTT to cloud platforms for unified portfolio-wide management.

Building Energy Management & Optimization

Stream building energy data to cloud analytics platforms for consumption tracking, demand response, and carbon reporting.

🔧

Remote Operation & Predictive Maintenance

Monitor HVAC, lighting, and equipment health via cloud dashboards — enable predictive maintenance and remote operations.

  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway
  • BACnet to MQTT Gateway

Want to get more information?

REQUEST A QUOTE
IIoT Gateway Manufacturer

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
Leave a message
FirstName *
LastName *
Email *
Message *
Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.