SNMP EdgeIO Controller BL193

No.BL193
SNMP edge controller that converts Modbus RTU/TCP data to standard SNMP OIDs. Supports SNMP v1/v2c/v3 with encryption. Built‑in MIB libraries. Expandable with 1-3 Y Series I/O boards. Perfect for data center monitoring, telecom base stations, and IT/OT integration. -40°C to +85°C.
  • Description

  • Model Selection

⚡ Industrial SNMP EdgeIO Controller

BL193 EdgeIO Controller

One device replaces "PLC + I/O modules + protocol converter". Seamlessly integrate OT equipment into IT monitoring via SNMP.
✔ OEM & ODM support ✔ -40°C ~ +85°C operation ✔ SNMP v1/v2c/v3 native
Product Overview

Bridge OT & IT with native SNMP

The BL193 is an industrial-grade SNMP EdgeIO controller from BLIIOT, purpose-built for environment and equipment monitoring in data centers, telecom base stations, and network rooms. It integrates data acquisition, logic control, and remote management. Supports 1–3 Y-series expansion slots for flexible I/O combinations — digital, analog, temperature, serial, pulse — converting industrial sensor/actuator signals into standard SNMP protocol without extra gateways.

Directly connect to existing NMS (Zabbix, SolarWinds, PRTG, OpenNMS) and unify infrastructure monitoring.

📡
Model: BL193
EdgeIO Controller

✔ 1–3 expansion slots
✔ Dual Ethernet daisy chain
✔ Isolated RS485

Why SNMP?

SNMP (Simple Network Management Protocol) is the de facto standard for IT network management, natively supported by all mainstream NMS platforms. For base station/equipment room monitoring, SNMP provides unmatched advantages:

Traditional OT Protocol Pain Points SNMP Advantages
OT and IT systems isolated, need dedicated gateway Industrial signals → MIB objects, native NMS recognition
No unified alarm format Trap active notification, no polling overhead
Difficult cross-vendor management Standard MIB library, unified OID identifier
Security depends on host PC SNMP v3 authentication + encryption (DES/AES), compliance ready
🔄 BL193 converts site data (temperature, humidity, smoke, water leak, UPS, A/C) into SNMP OIDs — monitoring alongside servers, switches, routers on the same platform.

Key Features & Capabilities

  • 🔌 Native SNMP ServerSNMP v1/v2c/v3, built‑in standard MIB, direct NMS integration
  • ⚙️ Flexible I/O expansion1~3 slots, 20+ Y‑series daughter boards: DI, AI, RTD, TC, pulse, etc.
  • 🔗 Dual Ethernet daisy chain2x 10/100M Ethernet with switch function, simplifies rack cabling
  • 📟 Isolated RS485Modbus RTU master/slave, collect smart meters (UPS, power meter) and convert to SNMP
  • 🌐 Built‑in Web ConfigBrowser-based logic programming (thresholds, conditional actions) – no proprietary software needed
  • 📡 Remote O&M (BLRAT)Remote firmware upgrade, parameter tuning, fault diagnosis – no site visit required
  • 🎛️ Local logic controlAutomatic alarm & interlocking (e.g., temp >35°C → fan start; water leak → alarm + trap)
  • 🔐 Secure communicationSNMP v3 user authentication & encryption (DES/AES), meets enterprise security policies

Technical Specifications – Base Controller

Power Supply
24V DC ±10%, 55mA@24VDC, reverse polarity protection
Ethernet
2× RJ45, 10/100M, isolated protection: ESD ±6kV/±8kV, EFT 1kV
RS485
1x isolated, baud rate 2400~230400 bps
Operating System
Linux, 300MHz CPU, 64MB RAM, 128MB Flash
Protocol Stack
SNMP v1/v2c/v3, HTTP, DHCP, DNS, Modbus RTU master/slave
MIB Library
Standard enterprise MIB, supports custom OID mapping
Operating Temp.
-40°C ~ +85°C, 5% ~ 95% RH (non-condensing)
Mounting
Wall mount / DIN35 rail, IP30 protection
Dimensions
1‑slot: 30×83×110 mm | 3‑slot: 40×83×110 mm

Typical Application: Remote Monitoring for Base Stations / Equipment Rooms

Background: A telecom operator had 200+ distributed base stations. Each station used PLC + touch panel + discrete I/O for temperature, smoke, water leak, door status, UPS. Manual inspection every two weeks, high cost, and unable to integrate data into the group’s Zabbix NMS — data silos.

✅ BL193 Retrofit Solution

  • Replace PLC + I/O with BL193, retain existing sensors & actuators.
  • Direct acquisition: DI (door/magnetic, smoke, leak rope), AI (temperature/humidity transmitter), RS485 (UPS, smart power meter).
  • Onboard logic: temp >35°C → DO start fan; water leak =1 → DO alarm + remote Trap notification.
  • BL193 acts as SNMP agent, maps all data to standard MIB objects and reports to central Zabbix NMS via existing network.
  • Unified monitoring dashboard: view server, switches, router health together with room temperature, UPS, A/C, leak status.
  • Engineers perform remote threshold changes, firmware upgrades, diagnostics via BLRAT tool — eliminating travel.

📉 Before retrofit

  • ▪ Hardware: PLC + I/O + HMI
  • ▪ Data platform: isolated silo
  • ▪ Alert response: manual patrol (2 weeks)
  • ▪ Site visits: ≥1 per month
  • ▪ Annual cost per site: ~8000 RMB

📈 After BL193

  • ▪ Single BL193 controller
  • ▪ Unified Zabbix NMS platform
  • ▪ Trap active alerts (seconds)
  • ▪ Only on‑site for installation/replacement
  • Annual cost ~1500 RMB (save >80%)

Conclusion: BL193 perfectly merges OT sensors with IT NMS, enabling “unattended operation, centralized management, remote maintenance” for equipment room monitoring.

SNMP Value Across Verticals

🏢 Data Center
PUE monitoring (hot/cold aisle temp, humidity, power) — unify with server/storage mgmt, simplify O&M.
📡 Telecom Base Station
Environment (temp, smoke, water leak, A/C, UPS) — Trap pushes instant alerts, saves bandwidth.
🌿 Campus / Smart Building
Substation temp, liquid level, lighting control — integrate into campus NMS, reduce platform cost.
🏭 Industrial Network
Industrial switch & PLC ambient monitoring — fill OT visibility gap, full-stack visibility.
🏬 Intelligent Building
Elevator status, pump room leak, HVAC parameters — leverage existing IT network, no dedicated BAS system needed.
🔌 Power / Energy
Remote equipment room monitoring, UPS/battery status via Modbus to SNMP conversion.

Environment & Certifications

🌡️ Wide operating temperature
-40°C ~ +85°C
🛡️ Protection rating
IP30
📜 EMC compliance
CE / FCC certified, IEC61000-4-2/4/5 Level 3 (ESD, EFT, Surge)
📳 Vibration & shock
IEC60068-2-6 (sinusoidal vibration), IEC60068-2-31 (free fall)

✅ Native SNMP v3 encryption/authentication
✅ Linux-based, future-proof
✅ 2x Ethernet switch + isolated RS485
✅ Custom OID mapping & MIB support

One device. Unified visibility.

Eliminate protocol silos — let your NMS talk directly to field I/O. BL193 is your industrial SNMP edge solution.

OEM / ODM ready | BL193 series | SNMP I/O gateway & controller

SNMP v1/v2c/v3 · MIB native · -40°C to +85°C · CE/FCC certified

Y‑Series I/O Selector

Compatible with BL192Pro, BL192, BL191, BL190, BL193, BA190, BA190Pro — 3 expansion slots.
🖱️ Click same module multiple times = select multiple slots (e.g., 3× Y31).

Available I/O Modules
💡 Click behavior: Each click adds that module to the next available slot.
🔁 Duplicate allowed: Click same module 2 or 3 times to fill multiple slots (e.g. Y31 + Y31).
⚠️ Y61 (Serial) can be selected only once per controller.
Your Selection (Slots 1–3)
    Total modules: 0 / 3
    Configuration summary
    No modules selected. Click any Y‑series module to occupy Slot 1 → Slot 2 → Slot 3.
    ✅ Fully compatible with BL192Pro, BL192, BL191, BL190, BL193, BA190, BA190Pro.
    📌 Each slot = physical I/O board position. Identical models allowed (click again).
    Y‑Series modules for BLIIOT Edge I/O Controllers. Up to 3 slots. Contact BLIIOT for custom configurations and volume orders.
    • snmp i/o module
    • data center
    • network management system
    • snmp io
    • nms
    • snmp i/o

    Want to get more information?

    REQUEST A QUOTE
    IIoT Gateway Manufacturer

    CONTACT US

    If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
    FirstName*
    LastName*
    Email*
    Message*
    Code*
    Verification Code
    Leave a message
    FirstName*
    LastName*
    Email*
    Message*
    Code*
    Verification Code
    We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.