SNMP edge controller that converts Modbus RTU/TCP data to standard SNMP OIDs. Supports SNMP v1/v2c/v3 with encryption. Built‑in MIB libraries. Expandable with 1-3 Y Series I/O boards. Perfect for data center monitoring, telecom base stations, and IT/OT integration. -40°C to +85°C.
The BL193 is an industrial-grade SNMP EdgeIO controller from BLIIOT, purpose-built for environment and equipment monitoring in data centers, telecom base stations, and network rooms. It integrates data acquisition, logic control, and remote management. Supports 1–3 Y-series expansion slots for flexible I/O combinations — digital, analog, temperature, serial, pulse — converting industrial sensor/actuator signals into standard SNMP protocol without extra gateways.
Directly connect to existing NMS (Zabbix, SolarWinds, PRTG, OpenNMS) and unify infrastructure monitoring.
📡
Model: BL193
EdgeIO Controller
✔ 1–3 expansion slots
✔ Dual Ethernet daisy chain
✔ Isolated RS485
Why SNMP?
SNMP (Simple Network Management Protocol) is the de facto standard for IT network management, natively supported by all mainstream NMS platforms. For base station/equipment room monitoring, SNMP provides unmatched advantages:
Traditional OT Protocol Pain Points
SNMP Advantages
OT and IT systems isolated, need dedicated gateway
🔄 BL193 converts site data (temperature, humidity, smoke, water leak, UPS, A/C) into SNMP OIDs — monitoring alongside servers, switches, routers on the same platform.
Key Features & Capabilities
🔌 Native SNMP ServerSNMP v1/v2c/v3, built‑in standard MIB, direct NMS integration
Standard enterprise MIB, supports custom OID mapping
Operating Temp.
-40°C ~ +85°C, 5% ~ 95% RH (non-condensing)
Mounting
Wall mount / DIN35 rail, IP30 protection
Dimensions
1‑slot: 30×83×110 mm | 3‑slot: 40×83×110 mm
Typical Application: Remote Monitoring for Base Stations / Equipment Rooms
Background: A telecom operator had 200+ distributed base stations. Each station used PLC + touch panel + discrete I/O for temperature, smoke, water leak, door status, UPS. Manual inspection every two weeks, high cost, and unable to integrate data into the group’s Zabbix NMS — data silos.
Conclusion: BL193 perfectly merges OT sensors with IT NMS, enabling “unattended operation, centralized management, remote maintenance” for equipment room monitoring.
SNMP Value Across Verticals
🏢 Data Center PUE monitoring (hot/cold aisle temp, humidity, power) — unify with server/storage mgmt, simplify O&M.
📡 Telecom Base Station Environment (temp, smoke, water leak, A/C, UPS) — Trap pushes instant alerts, saves bandwidth.
🌿 Campus / Smart Building Substation temp, liquid level, lighting control — integrate into campus NMS, reduce platform cost.
🏭 Industrial Network Industrial switch & PLC ambient monitoring — fill OT visibility gap, full-stack visibility.
🏬 Intelligent Building Elevator status, pump room leak, HVAC parameters — leverage existing IT network, no dedicated BAS system needed.
🔌 Power / Energy Remote equipment room monitoring, UPS/battery status via Modbus to SNMP conversion.
Compatible with BL192Pro, BL192, BL191, BL190, BL193, BA190, BA190Pro — 3 expansion slots. 🖱️ Click same module multiple times = select multiple slots (e.g., 3× Y31).
Available I/O Modules
💡 Click behavior: Each click adds that module to the next available slot. 🔁 Duplicate allowed: Click same module 2 or 3 times to fill multiple slots (e.g. Y31 + Y31). ⚠️ Y61 (Serial) can be selected only once per controller.
Your Selection (Slots 1–3)
Total modules:0 / 3
Configuration summary
No modules selected. Click any Y‑series module to occupy Slot 1 → Slot 2 → Slot 3.